LR-DT Concrete Chloride Ion Flux Tester is mainly used to evaluate the ability of concrete to resist chloride ion penetration. The specific uses and usage scenarios are as follows:
Purpose:
Electric flux test: By measuring the electric flux passing through the concrete specimen, the concrete's resistance to chloride ion penetration is further determined.
Durability evaluation: Provides a scientific basis for the durability design and life prediction of concrete structures, especially in chloride ion corrosion environments (such as marine environments or road bridges using deicing salt).
Usage scenarios:
Laboratory research: Used in scientific research institutions or university laboratories to study the resistance of concrete materials to chloride ion penetration and optimize concrete mix ratios.
Engineering quality inspection: In construction projects, it is used to detect the resistance of concrete structures to chloride ion penetration to ensure project quality.
Infrastructure maintenance: Used to evaluate the durability of existing concrete structures (such as bridges, tunnels, seaports, etc.) and formulate maintenance or repair plans.
Standard compliance test: Used to detect whether concrete meets the requirements for resistance to chloride ion penetration in relevant standards (such as ASTM C1202, GB/T 50082, etc.).
Marine engineering: concrete structures such as seaport terminals and cross-sea bridges that are exposed to chloride ion environments for a long time.
Traffic engineering: roads and bridges that use deicing salt.
Industrial buildings: environments that may be exposed to chloride ions, such as chemical plants and sewage treatment plants.
Civil buildings: concrete structures in humid environments such as basements and swimming pools.
Reference standards:
"Standard for test methods for long-term performance and durability of ordinary concrete" GB/T50082-2024
"Concrete structure durability design code" GB/T50476-2008
Working voltage | ~220VAC, 60VDC |
Voltage accuracy | ≤±0.1v |
Current accuracy | ≤±0.1mA |
Test time | 6 hours |
Color page LCD touch screen size | 7 inches |
Vacuum degree to 0.098MPa time | <4min |
Vacuum pump stop and start range | -0.098MPa~-0.095MPa |
Vacuum pump start interval | >2hrs |
Test channel
|
12 channels, can be customized according to user needs |