Lr-A001-D ISO 1133 Fully Automatic Melt Flow Index Instrument Plastometer Indexer
Lr-A001-D ISO 1133 Fully Automatic Melt Flow Index Instrument Plastometer Indexer, used for testing all kinds of plastic, resin in the state of viscous flow through a certain temperature and load, every 10 min module and melt flow rate through the standard port MFR/MVR value. Lr-A001-D ISO 1133 Fully Automatic Melt Flow Index Instrument Plastometer Indexer is suitable for high temperature of polycarbonate, aromatic sulfone, fluorine plastics, nylon engineering plastics, can also be applied to polyethylene (PE), polystyrene (PS), polypropylene (PP), ABS resin, polyformaldehyde (POM), polycarbonate (PC) resin with lower melting temperature, such as plastic test, widely used in plastic production,Plastic products, petrochemical and other industries and related institutions, scientific research units and commodity inspection departments.
Lr-A001-D ISO 1133 Fully Automatic Melt Flow Index Instrument Plastometer Indexer
Standard: GB/T3682-2018, ISO 1133:2011, ASTM D1238-13
Test Methods: MFR +MVR Methods
Display mode: English color touch screen display
Model | LR-A001-D |
Barrel parameters | Inner hole 9.550±0.005mm length 163mm |
Pistons head parameters | Piston head: 9.474±0.005mm |
Piston rod diameter | 8.94mm |
Mold length | 8.000±0.025mm |
Mold nominal inner diameter | 2.0955±0.0051mm |
Half die length | 4.000±0.025mm |
Half die nominal inner diameter | 1.050±0.005mm |
Temperature parameter | With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
Temperature range | Room Temperature~500degree centigrade |
Temperature fluctuation | ±0.2 ºC |
Temperature uniformity | ±1ºC |
Temperature display resolution | 0.1ºC |
Display resolution | 0.1ºC |
Maximum comsuption | < 600W |
Time display resolution | 0.1s |
Weight parameters are as follows: | |
Weight accuracy | ±0.5% |
Basic configuration
|
A 0.325kg |
B 1.2kg | |
C 2.16kg | |
D 3.8kg | |
E 5kg | |
F 10kg | |
G 12.5kg | |
H 21.6kg | |
Position detection | |
Loop distance from up and down | 30mm |
Control precision | ± 0.1mm |
Test flow control | |
Times of cutting the material | 0~10 times |
Material cutting interval | 0~999s(set reference Table 2) |
Control flow reaches the set temperature without volatility | |
Barrel temperature time | 15 min. |
Material be installed | 1 min. |
Material sample temperature recovery time | 4 min. |
When binder set | 1min |
Output mode | Micro-automatic print output |
Cut material methods | The hand automatic cut into one body |
Test load | Eight sets of weights |
Power | AC220V±10% 50/60HZ |