Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Programmable Temperature Humidity Chamber Constant Temperature and Humidity Test Chamber Test Instrument Machine
1. Design Standard
GB11158 | High Temperature Test Chamber Technical Condition |
GB10589-89 | Low Temperature Test Chamber Technical Condition |
GB10592-89 | High-low Temperature Test Chamber Technical Condition |
GB/T10586-89 | Damp Heat Test Chamber Technical Condition |
GB/T2423.1-2001 | Low Temperature Test Chamber Test Methods |
GB/T2423.2-2001 | High Temperature Test Chamber Test Methods |
GB/T2423.3-93 | Damp Heat Test Chamber Test Methods |
GB/T2423.4-93 | Alternating Damp-Heat Test Methods |
GB/T2423.22-2001 | Temperature Changing Test Methods |
IEC60068-2-1.1990 | Low Temperature Test Chamber Test Methods |
IEC60068-2-2.1974 | High Temperature Test Chamber Test Methods |
GJB150.3 | High Temperature Test Methods |
GJB150.4 | Low Temperature Test Methods |
GJB150.9 | Damp Heat Test Methods |
Programmable Temperature Humidity Chamber Constant Temperature and Humidity Test Chamber Test Instrument Machine
2. Product Specification
|
Benchtop Temperature and humidity test chamber LR-B001 |
Function
|
It simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance. It's required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard. |
Sample application
|
The chamber applies to: compatibility test for store, transportation and application of electric, electronic products, unit components, parts and other materials under high or low temperature. The following samples are prohibited to be tested and stored:
|
Volume, size & weight
|
|
|
49L W350 x D350 x H400mm W550 x D1100 x H950mm/W90 x D85 x H88cm 150KG |
Performance
|
|
|
Temperature:+25ºC , Humidity: ≤85%, no samples in the chamber |
|
GB/T 5170.2-1996 Temperature test chamber GB/T5170.5-1996 Temperature and humidity test chamber (only temperature and humidity) |
|
-20ºC→+150ºC (adjustable) |
|
±0.5ºC |
|
±2.0ºC |
|
20%~98%R.H (temperature at 20ºC-85ºC) |
|
±2.5%R.H. |
|
±3.0%. |
|
-20ºC → +150ºC Heat up for 2-4.0ºC/min |
|
+150ºC→ -20ºC Cooling for 0.7-1.0ºC/min |
|
Testing space is not more than 3/4 of the total space, no heating |
|
Stainless steel punching stencil |
|
![]() |