Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Suppliers with verified business licenses
1.Material of construction | ||
|
||
2.Technical parameters. | ||
Model No., equipment name | LR-B012-150 Xenon aging test chamber | |
Interior sizes | W500×D500×H600mm | |
Exterior sizes | W1050×D1050×H1750mm (or so) | |
Temperature range | 0ºC~80ºC | |
Controller | imported programmable 7inch touch screen | |
Machine components material | inner and outer 304# stainless steel | |
Sample holder | Aluminum alloy frame base | |
Protection device | residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. | |
Temp. deflection | ±2ºC (without lighting) | |
Humidity range | 30%~98%R.H | |
Humid. deflection | ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting | |
Light source | imported full spectrum xenon arc lamp(average useful life 1600hrs) | |
Raining time | 1~9999min (adjustable) | |
Raining period | 1~240min, interval(cut)adjustable | |
lamp power | Test period for Temp., irradiation, condensation, spray can be adjustable | |
Lamp | 1.8KW | |
Wave length range | 290-800nm | |
heating power (or so) | 4.0KW | |
humidification (or so) | 2.0KW | |
Light irradiance | ≤1200w/m2 | |
Distance between arc center and sample holder: | 350~380mm | |
Revolving speed of sample holder | ≥1r/min | |
water spray period | a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable) |
|
lighting time | Continuing programming control available | |
black panel temp. | 85±3ºC | |
cooling method | Mechanical wind cooling; Room temp. less than 26ºC is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. | |
3.Temperature & humidity running control system | ||
controller | imported programmable 7inch touch screen | |
precision range | set precision: temp. ±0.1ºC, humid: ±2%R.H, indicated precision: temp.±0.1ºC,humid.: ±1%R.H | |
temp. & humid. sensor | Platinum Resistance(PT100Ω/MV) | |
black panel temp. | double-metal black panel temp. thermometer | |
water-supplying system | auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water | |
circulation system | low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel | |
control system | mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. | |
4.Structure section of machine body | ||
The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. | ||
Chamber body |
|
|
external chamber body |
|
|
viewing window | Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass | |
5.Electric control section of chamber | ||
|
||
6.Working section of chamber | ||
Condensation section of compressor. A.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. B.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. C.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. D.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; |
||
Heating system |
|
|
Rain system. |
it consists of nozzle, solenoid valve, water-supplying and connecting pipe. | |
Lighting system. | It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. | |
Wind system | It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. | |
Cooling dehumidification system | take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. | |
Humidification | Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. |
|
Air circulation section | Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. | |
7. Enclosured files: operation manual, warranty card | ||
8. Machine running requirements | ||
Temp. | 5ºC~+32ºC | |
Humidity | ≤85% | |
Power supply | AC220(±10%)V/50HZ |