Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Management System Certification
ISO 9001
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
  • Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LR-4217
Type
Strength Testing Machine
Accuracy Grade
1
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Relative Humidity
<90%
Transport Package
Wooden Package
Trademark
Lonroy
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
1.Advantages


Complies with all current international standards. Able to analyze all current amino acids.
Two modules for Na-system: Regular/High-Speed analysis for 18~25 hydrolyzed amino acids.
Advanced temperature gradient combined traditional concentration and pH gradient is able to separate some amino acids which are difficult to be separated by traditional method.
Eluents consumption: 20%~30% of that of competitors' products.
Spare parts: no consumption.
Detector: An LED light source with a lifespan of more than 100,000 hours, no need to exchange the light source.
Built-in all-channel vacuum degasser, online degassing.
Ninhydrin and eluents are excluded from oxygen by nitrogen. Pressured nitrogen protection source.


Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
2.High pressure & high precision dual piston pump

Flow rate:0.000~9.999ml/min
Deviation of flow rate:0.1% (0.1ml/min)
Pressure range:0~40MPa
Seal: no need for a traditional seal
Automatically cleaning of the pump head to prevent clogging

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
3.High resolution separation column
Type:High theoretical number of trays
Resin:5μm/7μm cation exchange resin
Specification:typical/high speed/high resolution

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
4.Column oven with temperature gradient
Temp. control:Peltier
Temp. range:20~100°C
Precision: ±0.1°C
Temp. gradient separation control
Safety: auto-protection due to overheat/leakage of liquid

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
5.Maintenance -free detector
Type: High precision micro-diode photometer
Wavelength: 570nm and 440nm
High sensitivity, long life, no consumables

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
6.Autosampler
Dosing: full volume dosing/variable dosing
Number of position: 120
Dosing volume: 0 ~ 100μL

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
7.Room storage eluents
Eluents: 5 (Na-system)
Storage condition: ambient temperature
Shelf life: 1Year at least

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
8.High-effect reactor
Heating method: electronic, safety
Temp. range: ambient~150ºC
Precision: ±0.1ºC
High efficiency reaction, small dead volume, no diffusion
Safety: auto-protection due to power shut-off, auto-reset protection due to overheating.

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
9.Workstation for Amino Acid Analysis
Function:control, data collection and handling
Operation system:Windows
Language:Chinese/English

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
10.aminoPro-system control software
24 positions high precision professional data handling system, resolution 1μV, integral precision 0.05μV,amino acids word bank,double channel (570nm/440nm) merge, auto-identification of peaks and statistic function, data export.
Three-level administrative authority
Automatically recording 12 parameters of system condition per second.
Remote control, automatically stop system due to emergency
To avoid clogging of tubing, aminoPro can automatically clean the system due to power off by accident.
Per requirement of user, pre-set up different program. Making different data report. Offering electronic signature.
Product Parameters

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
11.Technical specifications

Environment Temperature requirement: 5~35ºC
Relative Humidity <90%
Power AC 110~240V,50~60±0.5 Hz
Repeatability of retention time RSD≤0.1% (Asp, Arg)
Repeatability for peak area RSD≤0.5% (Gly, His)
Detection limit <3pmol,≤2.5pmol (Asp),≤1pmol (His),  S/N=2
Resolution ≥98% (Thr-Ser),≥95% (Gly-Ala), ≥95% (Leu-Ile)
Linearity r≥0.999 (Gly);r≥0.999 (His)
Standard configuration
 
automatic amino acid analyzer host + reagent package + standard sample + proteolytic separation column + installationpackage + computer
Detailed Photos

Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and EluentsAmino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and EluentsAmino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and EluentsAmino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents


Amino Acid Analyzer Analyze 21 Hydrolysis Amino Acids or 43 Free Amino Acids Without Changing Column and Eluents
                             
A        2850K   2×60W     Incandescent             Sun-settting Light
             Yellow Li

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier