Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Suppliers with verified business licenses
High Temperature ISO 11358 Rubber Plastics Polymers TG TGA Thermogravimetric Analyzer
2.Structural advantage
1. The furnace body heating adopts double row winding of noble metal alloy wire, which reduces interference, high temperature resistance and oxidation resistance
2. The tray sensor has the advantages of wide test range, high temperature resistance, oxidation resistance and corrosion resistance.
3. The weighing system adopts imported weighing system, which has high stability and good repeatability.
4. Adopt upper open cover structure, easy to operate. It is difficult to move up the furnace body to put samples, which can easily cause damage to the sample rod.
5. The weighing system is sealed with constant temperature to reduce the influence of temperature difference on the weighing system.
6. The furnace body adopts double layer insulation, with low heat loss
7. The instrument heating using PID control, high precision, small pulse.
8. USB two-way communication is used between the software and the instrument, and the remote operation is fully realized. The parameters of the instrument can be set and the operation of the instrument can be stopped through the computer software
9. Program multi-stage setting, multi-stage temperature rise, constant temperature
The software sets the parameters of the instrument and stops the operation of the instrument.
10.7 "full color 24bit touch screen, better man-machine interface. Calibration of TG can be realized on the touch screen
Temperature range | Room temperature ~1150ºC |
temperature resolution | 0.01ºC |
temperature fluctuation | ±0.1ºC |
Heating rate | 0.1~100ºC/min |
Temperature control mode | PID algorithm control, heating, constant temperature, cooling |
Constant temperature time | 0 ~ 300min arbitrary setting |
Balance measurement range | 0.01mg ~ 3g, can be extended to 30gProgram control, realize multi-stage heating control |
DSC range | 0 ~ + 600mW |
DSC resolution | 0.001mW |
Precision of weighing system | 0.01mg |
constant temperature time | 0 ~ 300min arbitrary setting |
Display mode | 24bit color, 7 inch LCD touch screen display |
Atmosphere device |
built-in gas flowmeter, including two gas switching and flow size control |
Atmosphere | inert, oxidizing, reducing, static, dynamic |
Software | Intelligent software can automatically record TG curves for data processing and print experimental reports |
Curve scanning | Temperature scanning, temperature scanning |
Power supply |
The power supply and the weighing system have an isolation shield cover to avoid AC interference, AC220V 50Hz |
Operating software |
it can switch to meet the application switching test of differential, differential heat, thermogravimetric and synchronous heat |
Communication interface | USB communication |
The computer can draw temperature and TG and DSC curves during the test |