Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
BGD 862 Big Xenon Test Chamber Xenon Arc Lamp Testing Machine
Description:
This is a Big Xenon Test Chamber, using 6.5KW high-power precision water-cooled xenon lamp, exposure area of 6500cm2.
Feature:
*Powerful functions and reliable test results
* Meet all domestic and foreign xenon lamp test standard requirements.
* Adopt xenon lamp and filter components imported from the U.S.A. to ensure the comparability and reproducibility of test data.
* Automatic rotating three-layer drum type sample rack, to ensure that all exposure samples to obtain the same test conditions, * Exposure area up to 6500 square meters.
* Exposure area up to 6500cm2, and can expose a variety of different shapes and sizes of samples.
* The total test time or total irradiation energy can be set to end the test.
* Advanced xenon lamp cooling system and intelligent air conditioning system.
* Chinese and English operation interface conversion.
*Remote monitoring and cloud data service
* Remote monitoring of the xenon lamp mainframe operation of all conditions, to facilitate the user to manage data.
* Equipped with cell phone APP, users can monitor the operation of the equipment at any time.
*Direct setting and automatic control of various test parameters
* Direct setting and automatic control of irradiation energy (340nm, 420nm, 300nm-400nm, 300nm-800nm) Adjustment of irradiation energy deviation due to lamp aging and other reasons.
* Directly set and automatically control the studio temperature, blackboard temperature (BPT) and black standard temperature (BST), using a high-precision Pt 100 temperature sensor.
* Directly set and automatically control the studio humidity; ultrasonic humidification system, humidity is more uniform and stable.
* Directly set the spraying method (front spraying or back spraying), spraying time and spraying interval.
*Simple, easy to use, customizable
* Industrial control all-in-one computer touch screen menu operation control, friendly and convenient interface, the operator can arbitrarily set the test parameters and at any time to monitor the test process of each parameter running status.
* Pre-existing 6 most common standard test program, the operator can directly call out the use;
* Users can also according to their own needs to compile any test program and storage, the number of programs can be edited up to 9999 or more, and each program can be set to 30 different working conditions. Mass storage of user programs, flexible and convenient.
* With USB interface, the user can export all the experimental parameters of the instrument at any time, and automatically generate EXCEL table, which is convenient to check the running status of the instrument at any time.
* Standard with pure pressure water pump, provide constant water pressure for the equipment, while ensuring the spray volume is stable.
* Optional pure water system to meet the water requirements of the instrument.
* According to the actual needs of the user can be customized special test plate rack size, clamping mode, and so on;
*Safe and reliable
* A variety of alarm protection function: when there is a large irradiance error, pure water conductivity exceeds the standard, cooling water temperature is too high, cooling water tank water shortage, cooling water flow is too low, over-temperature, lamp power abnormality, the instrument will be automatically shut down and display the relevant alarm information in the operation interface.
* 24-hour professional online service, regular maintenance.
BGD 862 Big Xenon Test Chamber Xenon Arc Lamp Testing Machine
Ordering Information → Technical Item ↓ |
BGD 862 Plus Xenon Test Chamber |
Xenon Lamp |
6.5 KW water cooling long arc xenon lamp |
Light Filter |
Import originally from USA brand, can simulate indoor or outdoor sunshine spectrum |
Exposure Area |
6,500 cm2(63-65 pcs standard samples of 15cm×7cm size) |
Monitoring Method to Irradiance |
Four types:340nm,420nm,300nm~400nm,300nm~800nm Showing at the same time |
Adjustable Irradiance |
See Table B. |
Lifetime of lamps |
2,000 hours |
Adjustable Range of BPT |
RT~110ºC |
Adjustable Range of BST |
RT~120ºC |
Adjustable Range of Working room |
RT~70ºC(Dark) |
Temperature Stability |
±1ºC |
Temperature Uniformity |
≤2ºC |
Temperature Deviation |
≤ 1ºC |
Adjustable Humidity |
Light:10%-75% Dark:10%-95% |
Rotate speed of sample |
1 r/min(circle as lamp centre) |
Spray Function |
Can set spray continuous time and spray period |
Water Demands |
High purity deionized water(Conductivity<2us/cm) |
Compressed Air |
Clean,oilless compressed air with 0.5MPa pressure,Max. air supply is near 60L/min. Average air consumption is 10L/min~30L/min(Depends on testing standard) |
Flow of Deionized Water |
The water consumption for 24 hours is 300L-400L.(Taking the continuous run of cycle A for 24 hours in ISO 11341 standard as an example) |
Power Supply | AC380V±10%,Three-phase four-wire 50Hz;Max. Current 50A,Max. Power 9.5KW |
Overall Size |
1,220mm×1,200mm×1,970mm(L×W×H) |
Net Weight |
500 KG |