ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
1.Use
The UV Accelerated weathering test chamber stimulates dew and rain with consideration for humidity and/or water spray equipped with a fluorescent UV lamp which can completely simulate the UV spectra of sunlight, exposes materials to alternating cycles of UV light and moisture at controlled, elevated temperatures. It's most widely used weathering tester to test types of damages include color change, gloss loss, chalking, cracking, crazing, hazing, blistering, strength loss and oxidation. The source adopts 8 pieces of UV lamps of 40W as the light source. The lamps are distributed on the two sides of machine, 4 pieces for each side (UVA-340 and UVB-313 optional), 8 pieces in total .
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
2.Standard
Common standard:ISO 4892-1 ,ASTM G151 ,ASTM G154 ,JISD0205• SAEJ2020
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
3.Paint Standard
ASTM D3794 ,ASTM D4587 ,FED-STD-141B ,GM 9125P • JIS K 5600-7-8 ,ISO 11507 ISO 20340 ,M598-1990 ,NACE TM-01-84 ,NISSAN M0007 ,PrEN 927-6
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
4.Adhesive glue Standard
ASTM C1184 ,ASTM C1442 ,ASTM D904 ,ASTM D5215 ,UNE 104-281-88
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
5.Plastic Standard
ISO4892-3 ,ANSIC57.12.28 ,ANSI,A14.5 ,ASTMD4329 ,ASTMD4674 ,ASTMD5208 ,ASTMD6662 ,
DIN 53384 ,JUI K 3750 ,UNE35.104
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
6.Roofing materials standards
ANSI/RMAIPR-1-1990 ,ASTM D4799 ,ASTM D4811 ,ASTM D3105 ,ASTM D4434 ,BS D5019
BS 903: PartA54 ,CGSB-37.54-M ,DIN EN534
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
7.Printing,Ink material standards
ASTM D3424 ,ASTMF1945
ASTM G154 UV Weather Tester UV Accelerated Ageing Test Chamber
8.Fabrics Standards
AATCC TM 186 ,ACFFA Guideline
Main technical parameters | ||
Item | UV Lamp aging test chamber | |
Model | LR-B002-B | |
Interior size | W1150 X H400 x D500mm | |
Exterior size | W1350 X H1450 x D650mm | |
Weight | 120kgs | |
Controller | LCD 7-inch touch screen controller, with programmable temp., humid., UV(sun), and time and Fix mode of 2 running modes. USB interface Operation button Alarm indicator Irradiation timer |
|
Temp. control mode | PID self-adjustment SSR control | |
Temp. range | RT+10ºC ~ 70ºC (adjustable) | |
Temp. deviation | ±2.0ºC | |
Temp. fluctuation | ±0.5ºC | |
Humidity range | ≥93%R.H | |
Temp. uniformity | ±1ºC | |
Temp. fluctuation | ±0.5ºC | |
Distance between lamps | 75mm±15mm | |
Distance between samples and lamps | 100 ~ 50mm±30mm | |
Adjustment | Test period for Temp., irradiation, condensation, spray can be adjustable | |
Irradiation lamp | Lamp UVA-340, L=1200/40W, 8pcs (average service life: 1600hrs) | |
Temp. control method | PID self-adjustable SSR control | |
Depth of water channel | 25mm under auto-control | |
UV Wavelength | UVA-340: 315 ~ 400nm; | |
Test time | 0~999 H 99 min (adjustable) | |
Function | Temperature, light, condensation, spray test cycle is adjustable | |
Black board Temp. | 50ºC ~ 70ºC (temperature inside the chamber plus 20ºC ~ 25ºC) | |
1.Structure & Material | ||
Structure: 1.The middle of the machine is the working chamber, the water system located at the bottom of machine, its top is the control cabinet and control panel. Open the door from front direction. The bottom of the chamber with high-quality PU activity wheel that can be fixed, users can move it according to their requirements positioning. 2.Single cycling system for air flue in the box, there's one inlet axis weeding machine which improves the flow amount of air, the heating ability and the whole temperature uniformity in the test machine. Water source and consumption: Tap water or distilled water for 8liters per day. 3.Heating method is to heat liner water tank with fast heating speed and high temperature uniformity. Material: 4.Inner box: high grade stainless steel plate 5.Outer box: stainless steel plate SUS304 or stoving varnish for option. |
||
1.Spray System | ||
1.Using the manual control function of the controller, to observe the spray condition in the open-door state, so as to adjust or replace the nozzle. 2.The machine is equipped with a sprinkler, the sprinkler simulates the temperature upheaval and rain erosion during the rain, with a total of several nozzles, sprayed evenly. The spray time is set by the customer. 3.Inner water level is with automatic water replenishing. |
||
1.Light source system | ||
Types of light source (simulate the sunlight) Light source: 4 imported UV fluorescent lamps (ATLAS) with rated power of 40W, UVA-340 and UVB-313 light source for users to choose. Like other lamps, the aging of the QUV tube causes the lamp output to drop, and the QUV without the Irradiance meter control system uses the rotational position method to compensate. This system can be used for many application standards, but it has inherent limitations. This method of changing position does not compensate for the effects of different batches of lamps or the surrounding environment. ![]() Fig. - Lamp replacement method. 2.UVA-340: A wavelength that emits sunlight from 365 nm to 295 nm, and its radiation peak is at 340 nm. UVA-340 is especially useful for control tests in different tests, with the best simulation of sunlight in the short-wave UV range. ![]() 3.UVB-313: The wavelength range is between 280 nm and 315 nm. UVB-313 ages faster than UVA-340 lamps, but their shorter wavelengths than the sun cutoff point can have unrealistic results for many materials. ![]() |
||
2.UV Cycle Temperature control | ||
The components of the UV cycle system include a blower, air heater, air distribution system, and blackboard temperature sensor. 1.Blower: Installed in the lower tank air duct of the equipment, the blower is continuously operated throughout the UV cycle. 2.Air heater: Installed in the air duct above the blower to heat the air blown by the blower when needed. 3.Air distribution system: The air blown by the blower enters the test chamber through the air duct, and then the air guide to the entire chamber. |
||
3.Heating system | ||
1.High speed heating tube of U-shape titanium alloy; 2.independent temperature control system and lighting system; 3.temp. control and output power controlled by micro computer with high accuracy and high efficiency. 4.Thermal protection function of heating system. 5.The black panel adopts the colorful touch screen controller or digital key pressing controller to control the heating process. PID self-regulation, monitoring all adopt the standard PT100 temp. sensor of black panel. Temp. of water tank adopts the colorful touch screen touch screen program to control the heating, water tank locates at the bottom of tank, there is electrical heating device. During the test process, there's test phase is dark condensation which need to generate saturated steam of high temperature, when steam meet the cool temperature, it condenses into water on its surface. |
||
1.SB port (standard) | All the history curve and history data can be downloaded from controller as Excel or JPG according to date. |
|
Standards compliant | ||
GB/T14552-2008 "National Standard of the People's Republic of China - Plastics, Coatings, Rubber Materials for Machinery Industry - Artificial Climate Accelerated Test Method", a, fluorescent UV / condensation test method. GB/T16422.3-1997 GB/T16585-96 Relevant analytical methods. GB/T16585-1996 "National Standard of the People's Republic of China - Test Method for Artificial Weathering of Fluorinated Rubber (Fluorescent UV Lamp)". GB/T16422.3-1997 "Plastics Laboratory Light Source Exposure Test Method" and other corresponding standard terms and design standards. In line with international testing standards: current ultraviolet aging test standards such as ASTM D4329, ISO 4892-3, ISO 11507, SAE J2020. |
||
Safety protection device | ||
1.Ground protection 2.power source overload and short circuit breaker 3.control loop overload and short circuit fuse protector 4.water shortage protection 5.thermal protection |
||
Quality assurance system Sailham strictly follows the requirements of ISO9001:2015 quality management system and European CE product certification. |
||
Standard accessories attached to machine | ||
Stainless steel SUS # 304 Shelf layer 1pc Power cord 1pc A drain hole (8 mm in diameter) Operation and maintenance instructions 1 copy Controller manual 1 copy Warranty card 1 copy |
||
Equipment ambient environment Grounding resistance cable is less than 4Ω; Requires users to configure the device at the installation site for the capacity of the air or power switch, and the switch must be independent for the device (plug-socket is not allowed); Temperature: 5ºC ~ +30ºC Humidity: ≤85% Pressure: 86kPa ~ 106kPa Power supply: AC220 (±10%) V, 50 / 60HZ Power: 4.5KW |