IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Management System Certification
ISO 9001
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
  • IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LR-B009
Type
Thermal Shock Chamber
Accuracy Grade
1
Weight
100-500Kg
Power Source
AC380V
Preheating Temperature Range
60-180 Degree
Transport Package
Wooden Package
Specification
W500× H400× D400mm
Trademark
Lonroy
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description
 
Product Name
two-box cold and hot shock test chamber

Product Model
LR-B009


Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber With Two Zone
1. Product
Brief Introduction

1. Scope of application
This series of cold and heat shock test box is suitable for alternating shock test of electrical and electronic products and electronic parts.
2. Applicable standard
Products can meet CNS, MIL, IEC, JIS, GB/T2423.5-1995, GJB150.5-87 and other standards


Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber With Two Zone
2. Control Mode

Using low temperature and high temperature hot and cold storage tank, in accordance with the action to open the valve, the low temperature and high temperature to test by air supply system fast fast groove, so as to achieve rapid temperature shock effect, balance (BTC) + special temperature control system design of supply air circulation system, to control SSR P.I.D. way, make the system of heat equal to the amount of heat loss, thus the use of long-term stability.
Product Parameters

Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber With Two Zone
3. Technical
Parameters

Temperature impact range High temperature 60ºC~+150ºC
Low temperature -40ºC~-10ºC
Preheating temperature range +60ºC ~ +180ºC
High temperature tank heating time RT(indoor temperature)~+180ºC takes about 40min
 (room temperature is +10 ~ +30ºC).
Pre-cooling temperature range -10ºC~-55ºC

Cooling time of cryogenic tank

 
RT (room temperature) ~ -55ºC for about 50min (room temperature +10-- +30ºC)
Temperature fluctuation ±1.0ºC
Temperature Uniformity ±2.0ºC
Impact recovery time -40-- +150ºC for 5min.
The high and low temperature impact constant temperature time is above 30min

Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber With Two Zone
4. Product
Mix

Inside Dimension
W500×H400×D400 mm

Carton Size
W1230×H2250×D1700 mm
In the cases of material Fogged stainless steel plate(SUS#304)
Carton material Sand-lined stainless steel plate(SUS#304)
Heat preservation material a. High temperature tank: aluminum silicate insulation cotton.
b. Low temperature tank: HIGH density PU foam.
Door Upper and lower monolithic doors, open on the left.
a. Embedded flat handle.
b.After the button:SUS#304.
c.Silicone foam rubber strip.

Testing rack
a.The hanging basket size:W500 x D400mm.
b.No more than 5KG.
c.Stainless steel SUS304 inner case..

Heating system
Finned radiator type stainless steel heater.
1.High temperature tank  6 KW.
2.Cryostat  3.5 KW.

Air circulation system

 
1.Motor 1HP×2 Platform.
2.Stainless steel extension shaft..
3.Multi-wing fan blade(SIROCCO FAN).
4.Specially designed fan forced air circulation system.
Refrigeration System
Adopt multi - section automatic load capacity adjustment technology, more efficient, more energy - saving
Pressure reduction machine Imported French "Taikang" brand semi-enclosed compressor
Cold condenser Fin - mounted cooling fan
Hair steamer

 
Finned multi - segment automatic load capacity adjustment
 
Bulk expansion valve Imported from Denmark
Refrigerant R404A imported from USA
Make cooling auxiliary parts Desiccant (Denmark), oil separator (USA), refrigerant window (Denmark), solenoid valve (Japan), filter (Japan), pressure controller (Korea), globe valve (Italy) and other refrigeration parts are imported
Protector
Zero crossing brake fluid power controller
Heating air burn protection switch
Compressor overpressure protection switch
Compressor overload overcurrent protection switch
Phase loss protection switch
No fuse overload protector
Quick heating insurance
Master Controller
Touch-screen direct button controller, Chinese and English 7 "graphics wide view, high contrast with adjustable backlight function of large LCD LCD controller.
1.Controller specification:
a. Precision: temperature ±0.1ºC+1digit.
b. Resolution: temperature ±0.1.
c. It has upper and lower standby functions and alarm functions.
d. Temperature input signal T-type.
e.P.I.D control parameter setting,P.I.D automatic calculation.

2.Screen display function:
a. Screen chat, no need to press the button to enter, direct touch screen options.
b. Direct display of temperature setting (SV) and actual (PV) values.
c. Display the fault status and explain the troubleshooting method.
d. Display the current program number, duration, remaining time and number of cycles.
e. The setting value of temperature program is displayed by graph curve, with the function of real-time display program curve execution.
f. With a separate program editing screen, temperature, time and cycle times can be entered.
g. The screen can be backlit.
h. Screen display protection can be used for timing, TIMER or manual off Settings.

3. Program capacity and control function:
a. Available program group: maximum 96 PATTEN(i.e. 96 test specifications can be set).
b. Repeatable execution of commands: each command can be executed 999 times.
c. Ments time setting 0--99Hour59Min.
e. It has the memory of power off program, and automatically starts and continues the program function after power back on.
f. Real-time display of graphic curves during program execution.
g. Reservation startup and shutdown functions.
h. With date and time adjustment functions.
Primary Clustering
1.Ac contactor: France
2.Thermal relay: France
3.Ac relay: France
4.Time relay: France
5.Controller: Independently developed
6.Overtemperature protector: Taiwan
7.Power master switch: Taiwan
8.Solid state relay: Taiwan,
9.Button switch: Taiwan
10.Dry burn protector: Italy

Supplementary Instruction
Make the electric voltage: AC3¢5W 380V 50/60Hz.
Voltage variation allowable: ±10% of the fixed voltage.
Environment
Allowed environment: 0 ~ 30ºC
Performance assurance environment: 5 ~ 25ºC
Do not place other objects within 60CM around the instrument
Items not included in the appraisal
1. Preparatory work for the establishment of the site
2. Electrical equipment on the input side
3. Electrical wiring on the input side

 
Detailed Photos

IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two ZoneIEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone

IEC 60068 Two Box Cold Heat Shock Test Chamber Constant Temperature Change Thermal Shock Cold and Hot Shock Test Chamber with Two Zone

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.