Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Breathable Aging Test Chamber Wire and Cable Ventilated Aging Test Chamber
2.Features
1. The outside is treated with SECC steel plate and fine powder baking paint, and the inside is made of SUS stainless steel;
2. New high-temperature resistant long shaft motor
3. Vortex fan
4. Silicon Packing
5. Over-temperature protection: over-load automatic power-off system
6. Circulation mode: forced horizontal air supply circulation
7. Heating method: PID+S.S.R
8. Temperature range; Indoor degree +20-260 degrees; Note: The temperature is adjustable
9. Thermostat: PID microcomputer control
10. Timer: temperature to time, time to cut off the heating power
11. VA2-101 and VA2-150 are equipped with glass window, and VA2-270 and above models have no glass window.
14. There are inlet and exhaust devices
15. High temperature protection and overcurrent protection
Model | LR-V101 | LR-V150 | LR-V270 |
Internal dimensions (WHD) mm | 450*500*450 | 500*600*500 | 600*900*500 |
External dimensions (WHD) mm | 650*1000*620 | 700*1160*660 | 830*1580*680 |
Heating time | RT-260 °C for about 45 min | RT-260 °C for about 45 min | RT-260 °C for about 45 min |
precision | ±0.5ºC | ±0.5ºC | ±1.0ºC |
Uniformity | ±1.0ºC% | ±1.0ºC% | ±1.0ºC% |
voltage | 50HzAC,220V,1PH | 50HzAC,220V,1PH | 50HzAC,220V,1PH |
current | 2.5kw | 3KW | 5KW |
Grids | It is divided into two layers of grid plates and 2 pieces | It is divided into four layers and 2 grids | It is divided into eight layers and 4 grids |
remark | Single door | Single door | Single door |