ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Management System Certification
ISO 9001
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
  • ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μ M-800μ M
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LR-N008
Type
Particle Size Analyzer
Accuracy Grade
1
Weight
25kg
Power Source
AC220V
Transport Package
Wooden Package
Trademark
Lonroy
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1μm-800μm

LR-N008 spray particle size meter adopts split design, which can be used in a wider range.  More stable performance, larger range, suitable for a variety of complex test environment, at the same time,
LR-N008 dust treatment.  

Main performance characteristics
The LR-N008 uses a split structure to test samples at a distance. The LR-N008 uses a large platform and can be used for normal testing at a distance of 0.1 m to 10 m even when used as an integral unit.  
1. Advanced optical path design
LR-N008 adopts fraunhofer diffraction principle and typical parallel optical path design, and is equipped with high-power semiconductor laser.  The unique high-density detection unit enables the LR-N008 to have a strong ability to test small particles. The LR-N008 can test seamlessly within 1μm to 800μm.  At the same time,LR-N008 is equipped with light path automatic adjustment device, which is convenient for operation and prolongs the service life of the instrument.  
2. High power semiconductor laser
The LR-N008 uses a high-powered semiconductor laser to enhance the resolution of the instrument and make it impossible for small particles to hide.  
3. Automatic calibration of optical path:  
Pw180-b is the first spray particle size meter to add automatic alignment function, LR-N008 added light path automatic adjustment system, to ensure the stability and accuracy of instrument measurement.  At the same time greatly reduce the operator's working intensity.  
4. Imported lens
LR-N008 adopts Japanese Canon as the main lens, which has small distortion and high imaging. The receiving end adopts a large diameter long focal length lens with a diameter of 150 mm, which makes particle detection more accurate.  
5. Ultra wide range
LR-N008 ranges from 1μm to 800μm.  
Auxiliary light positioning: LR-N008 uniquely adds the auxiliary light positioning function, during positioning, two laser beams are emitted at the transmitter end at the same time, and the receiver end can start the automatic optical path adjustment system after the double point matching, which greatly simplifies the adjustment difficulty.  
6. Powerful analysis software
Powerful analysis software can record the particle size distribution of all fog droplets in all laser beams at any time.  Moving spray test results within the laser beam can be continuously recorded and statistically analyzed.  
Product Parameters

Technical parameters

specifications   LR-N008
Execution standard   ISO 13320-1:1999;GB/T19077.1-2008
Test range   1μm-800μm
Number of detector channels   66
Accuracy error   <1% (national standard sample D50 value)  
Repeatability error   <1% (national standard sample D50 value)  
Sample way   Open injection  
Instrument structure   Split or one piece optional  
Split guide (optional)   Split instrument, test area within 3 meters can be optional guide rail  
Laser parameter   Imported fiber output high power laser λ= 650nm, power 1-40MW adjustable  
The key parameters  
 
 
 
 
 
Measurement area  
The lens  
Split type: the instrument can be normally tested in the range of 0.1 to 10 meters  
All-in-one: instrument 0.1m to 2.4m  
The lens to protect   Canon high performance lens  
Sample way   Air curtain protection  
In the automatic to  Spray (including fog drops and solid powder)  
Measurement area   The instrument automatically adjusts the light path, and the computer software automatically completes it with one key.  
Software functions   Analysis patterns   Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods  
Statistical methods   Volume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries  
Statistical comparison   It can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials  
To DIY   User-defined data to display, according to the percentage of particle size, according to the percentage of particle size or according to  
According to the template   The percentage of particle size interval is calculated to meet the characterization of particle size test in different industries.  Diameter distance, consistency, interval accumulation, etc  
The test report   The test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion  
Multilingual support   Chinese and English language interface support, can also be embedded in other languages according to user requirements.  
Operating mode   Computer operation  
The test speed   The < 1 min/time  
The weight of the   25Kg  
Detailed Photos

ISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1&mu; M-800&mu; MISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1&mu; M-800&mu; MISO 13320 Automatic Spray Laser Particle Size Analyzer Laser Diffraction Analyer 1&mu; M-800&mu; M

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier