408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Gold Member Since 2025

Suppliers with verified business licenses

Management System Certification
ISO 9001
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
  • 408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
LR-B001
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Transport Package
Wooden Package
Trademark
Lonroy
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

408L 1000L Low Temperature Test ChamberHigh Temperature Test Chamber Damp Heat Test Chamber 
1.Test Standard
GB11158 High Temperature Test Chamber Technical Condition
GB10589-89 Low Temperature Test Chamber Technical Condition
GB10592-89 High-low Temperature Test Chamber Technical Condition
GB/T10586-89 Damp Heat Test Chamber Technical Condition
GB/T2423.1-2001 Low Temperature Test Chamber Test Methods
GB/T2423.2-2001 High Temperature Test Chamber Test Methods
GB/T2423.3-93 Damp Heat Test Chamber Test Methods
GB/T2423.4-93 Alternating Damp-Heat Test Methods
GB/T2423.22-2001 Temperature Changing Test Methods
IEC60068-2-1.1990 Low Temperature Test Chamber Test Methods
IEC60068-2-2.1974 High Temperature Test Chamber Test Methods
GJB150.3   High Temperature Test Methods
GJB150.4 Low Temperature Test Methods
GJB150.9 Damp Heat Test Methods
408L 1000L Low Temperature Test ChamberHigh Temperature Test Chamber Damp Heat Test Chamber 
 2.Product Paeameter
  1. Item
  2. Model
Constant Temperature and humidity test chamber
408L,1000L
  1. Function
It simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance.
It's required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard.
  1. Sample application
The chamber applies to:
compatibility test for store, transportation and application of electric, electronic products, unit components, parts and other materials under high or low temperature.
The following samples are prohibited to be tested and stored:
  • Inflammable , explosive and other volatile substances;
  • Corrosive substance;
  • Biont;
  • Strong electromagnetic emission source.
  1. Volume, size & weight
    1. Volume
    2. Internal size
    3. Exterior size
    4. Weight
408L                               1000L
W 600 x H850 x D800mm       W 1000 x H1000 x D1000mm
W900 x H1810 x D1800mm     W1300 x H2000 x D2100mm  
400KG                           600KG
  1. Performance
    1. Test condition
Temperature:+25ºC, Humidity: ≤85%, no samples in the chamber
    1. Test method
GB/T 5170.2-1996 Temperature test chamber
GB/T5170.5-1996 Temperature and humidity test chamber (only temperature and humidity)
    1. Temperature range
-40ºC→+150ºC (can customize -70ºC)
    1. Temperature fluctuation
±0.5ºC
    1. Temperature accuracy distribution
±2.0ºC
    1. Humidity range
20%~98%R.H (temperature at 20ºC-85ºC)
    1. Humid. fluctuation
±2.5%R.H.
    1. Humidity accuracy distribution
±3.0%.
    1. Heat-up time
-40ºC → +150ºC  Heat up for 2-4.0ºC/min
    1. Cooling time
+150ºC→ -40ºC Cooling for 0.7-1.0ºC/min (customzie 3ºC/min)
    1. Load condition
Testing space is not more than 3/4 of the total space, no heating
    1. Sample holder
Stainless steel punching stencil
    1. Relative humidity and temperature control range (refer to fig.)
 
    1. Meet the technical standards



 
GB/T 2423.1-2001 Test A: Low temperature test method
GB/T 2423.2-2001 Test B: High temperature test method
GJB 150.3-1986  High temperature test
GJB 150.4-1986  Low temperature test
IEC68-2-1 Test A: Cold
IEC68-2-2 Test B: Dry heat
GB11158 "Technical Conditions for High Temperature Test Chamber "
GB10586-1 "Technical conditions for Damp heat test chamber "
GB/T 2423.2 "Basic environmental testing procedures 
for electric and electronic products B: High temperature test method".
GB/T 2423.3 "Basic environmental testing procedures 
for electric and electronic products Ca: Constant damp heat testing method" etc.
  1. Structure characteristics.
    1. Insulated enclosure structure
External material: SUS304 or stoving varnish or coating outside
Inwall material: SUS304
Insulation material of box body: flame retardant fire rigid polyurethane foam
Door thermal insulation material: flame retardant fire rigid polyurethane foam
    1. Air conditioning channel
Centrifugal fan:
Heater, evaporimeter, outfall, temperature sensor
    1. Test chamber standard
Window 330x450x40mm 3 vacuum layers
Anti-explosion handle
Door hinge: SUS #304
Lamps in the chamber: 11W
Access port: φ50mm or φ100mm 1pc or more.
    1. Door
Single door, open from left, handle is at right; With viewing window: W300xH450mm, lamp window/condensation prevention thermal device
    1. Controller
Control screen, overtemperature protection setting
    1. machine room
Refrigeration units , water pans , outfall
    1. control cabinet for power distribution
Switchboard fan, ventilator
    1. Heater
Heating system: cycling heating from finned-tube Stainless steel electric heater
    1. Humidifier
Oven humidification system, cycling winding system
    1. Power line hole and outfall position
located at the back of chamber
  1. Cooling system (Binary cascade refrigeration)
    1. Cooling compressor
Tecumseh (France)
8.3. Evaporator fins-tube evaporator
8.4. Condensator Air-coolled tube-type condensator  
8.5 Expansion system Refrigeration system of volume control (capillary)
8.6 Evaporative condenser Stainless steel brazing plate-type heat exchanger
 
8.7 Chiller control
 
Operation of cooling machine can be adjusted automatically by control system according to the test condition
evaporating pressure adjustable valve
Cooling loop of compressor
8.8 Freezing medium  R404a (Eco-friendly, Ozone loss rate at 0)
  1.  Controller
 Independent R&D software (Taiwan)
9.1 Temperature and Humidity controller Imported 7.0 inch LCD touch screen control, programmable of temperature and humidity; 100 groups of program and 1000 groups of memory, each for 99hrs 59min and can be set as required with groups of PID control function.
9.2 Controller specifications Precision: Temp. ±0.1ºC+1digi, humid.: ±1%R.H+1digit
Distinguishability: Temp.: ±0.01ºC, humid.:±0.1%R.H.
slope temperature; 0.1~9.9 adjustable.
With warning function and up& down limitation standby
9 groups of PID control parameters and PID auto-calculation.
Dry and damp ball with auto correction.
9.3 Function of page display, program volume and control function
  • Touch screen operation, no need to input by key pressing;
  • Temp. and Humid. Set (SV) with true (PV) value shown.
  • Display of current program No., phase, time left and cycling times.
  • Run the operation of accumulative time.
  • Program set value of Temp.& humid. shown as curve;
  • At least 5 phase of temp. & humid, time can be input on the sole program editing page.
  • Language can be switched between English and Chinese;
  • Fault page shown;
  • Back light adjustable of screen;
  • Protection function can be set by time, TIMER can be turn off by manual;
  • Program groups available: 100 max. PATTEN.
  • Memory volume available: 1000 SEGMENTS.
  • Repeat executive command: up to 90 times for each command.
  • Program with editing, cancel and insert available;
  • Time set of SEGMENTS: 0~90Hour59Min;
  • Module device controlled by program;
  • Electricity cut memory, with auto start-up and executive program function after switch on;
  • program execution with display of curve diagram;
  • With auto adjustable freeze function;
  • Reservation of start-up and turn-off available;
  • Data and time adjustable;
  • Key-pressing and page lock (LOCK) available.
  1. Safety protection device
    1.  Cooling system
  • compressor overheated
  • compressor overflowed
  • compressor overpressed
  • condensate fan overheated
  • oil pressure protection of compressor
    1. Test chamber
Adjustable overheat
Air conditioning channel overtemperature limit
Wind motor overheated
    1. Other
  • phase sequence and open phase protection of main power supply
  • leakage protection
  • heating, humidification and Dry burning-resistant protection
  • overload and short circuit protection
  • overtemperature outage protection
  1. Other equipped parts
    1. power control contactor of sample testing
Contactor of relay control: within AC220V, 2A (contactor closed under normal running, when chamber stops or of malfunction, contactor open).
    1. leakage breaker of main power supply
AC220V, 50Hz+Grounding wire.
  1. Accessories
    1. Power
(Standard)
Five core single-phase three-wire and 1piece of protection grounding wire (optional)
    1. Access port
φ50mm, φ80mm, φ100mm, φ120mm available according to your requirement and cab be customized on the premise that not affect the machine performance.
    1. USB interface (Standard)
All the history curve and history data can be downloaded from controller as Excel or JPG according to date.
    1. Remote Control System  (optional)
 
13  Transportation The chamber as a unitary to be transported
    1. Delivery size
    2. Weight
Max. size (package not included): refer to "exterior size"
Max. delivery weight (package not included): refer to "Weight"
14 Usage requirements Assured by users as below requirements
14.1 Installation position - With leveling ground and good ventilation;
- No strong shock near the chamber;
- No strong electromagnetic field near the chamber
- No inflammable , explosive , corrosive material and dust
- Surrounding size for chamber operation and maintenance:
A: not less than 10cm
B: not less than 60cm
C: not less than 60cm
D: 225 type: not less than 80cm
408 type: not less than 90cm
1000 type: not less than 120cm
14.2 Condition Temperature: 5ºC~30ºC
Humidity: ≤85%
Air pressure: 86kPa~106kPa
14.3 Tap water: only for damp heating equipment with pure water machine Water flow ≥200kg/h, pressure: 0.1Mpa ~ 0.25Mpa.
Tap water conforms to GB 5749-1985 drinking water standard; Remark: equipped with DN15 male adapter of pure water machine
14.4 Power supply condition






Total power
Max. current
Voltage
  • AC220V + Protection grounding
  • Voltage fluctuation range: AC(220±10%) V
  • Frequency fluctuation range: (50±0.5)Hz
  • Resistance of protection grounding wire less than 4Ω.
  • It's required to equipped with air or motive switch of corresponding capacities, which is also used only for the chamber

3.8 KW
16A
380V

Company Profile

408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber
408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber

408L 1000L High Low Temperature Test Chamber Damp Heat Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier